Battery projectile testing machine
The structure of Battery projectile testing machine Integrated construction with door-mounted explosion-proof lock + explosion-proof chain
The structure of Battery projectile testing machine Integrated construction with door-mounted explosion-proof lock + explosion-proof chain
1. Related test requirements
1.1 UL1642
1.2 GB31241-2014
|
Model |
MBS-RS31241 |
|
Structure |
Integrated construction with door-mounted explosion-proof lock + explosion-proof chain |
|
Burner |
Bunsen burner, with pipe ID being 0.375’’ (9.5mm) and length being approx. |
|
Flame duration |
99H 59M 59S |
|
Flame height |
10~75±2mm (adjustable) |
|
Test bar diameter |
1/4’’ (6.35mm)x14’’(355.6mm) |
|
Test cage |
Distance between two parallel sides: 24’’ (610mm) Height: 14’’ (305mm), eight-sided Angle: top and bottom width 12.7mmx12.7mm |
|
Flame height |
Steel wire mesh placed at approx. 38mm above the flame |
|
Test aluminum wire diameter |
0.010’’ (0.25mm) 16 meshes x 16 meshes |
|
Eight-sided stainless steel screen cover |
Distance between two opposite sides: 2 feet (610mm); eight-sided screen cover height: 1feet (305mm) |
|
Test hole surface diameter |
102mm |
|
Igniter |
Automatic ignition |
|
Display mode |
PLC touch control + remote control |
|
Inspection window |
390x360mm (20mm thick explosion-proof glass), with stainless steel screen added for explosion protection |
|
Control mode |
Remote control; automatic control of the test process |
|
Burning gas requirement |
Highly pure liquefied petroleum gas (user supplied) |
|
Data export |
Test data can be directly exported with USB flash disk in the form of screenshot. |
|
Safety protection system |
Explosion-proof pressure relief device, exhaust device, fire extinguishing system, electronic door lock system, safe stop switch |
|
Optional parts |
Temperature acquisition system, voltage acquisition system, video monitoring system |